Detcon Model FP Transmitter Test Fixture Page 3 of 3 1.0 Description The Detcon Model FP Transmitter Test Fixture is designed to test the operation o
Detcon Model FP Transmitter Test Fixture Page 4 of 4 3.0 Specifications Compatible with the Following Models Model Series FP-424x, FP-524x, FP-
Detcon Model FP Transmitter Test Fixture Page 5 of 5 3 - Check the bridge voltage. Insert DVM probes into the bridge “+” and “–“ test points. Adjust
Detcon Model FP Transmitter Test Fixture Page 6 of 6 b) Next, scroll to the “SET BRIDGE VOLTS” listing and then hold the programming magnet over “PG
Detcon Model FP Transmitter Test Fixture Page 7 of 7 6 - Check different ranges. Turn SW1 to each position (10, 20, 50, 100) and verify a matching tra
Detcon Model FP Transmitter Test Fixture Page 8 of 8 c) Use the programming magnet to make an adjustment to “PGM 1” to increase or “PGM 2” to decrea
Detcon Model FP Transmitter Test Fixture Page 9 of 9 NOTE: Optimally, when SW1 is in the 100% LEL position, the FP-524 display will indicate a flashi