Detcon PI-700 Manual de usuario

Busca en linea o descarga Manual de usuario para Sensores Detcon PI-700. Detcon PI-700 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 64
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
INSTRUCTION MANUAL
Detcon Model PI-700
PI-700 VOC Gas Sensors
This manual covers all ranges of PID based VOC Sensors
DETCON, Inc.
4055 Technology Forest Blvd.,
The Woodlands, Texas 77381
Ph.281.367.4100 / Fax 281.298.2868
www.detcon.com
April 15, 2014 • Document #3228 • Revision 2.5
Vista de pagina 0
1 2 3 4 5 6 ... 63 64

Indice de contenidos

Pagina 1 - Detcon Model PI-700

INSTRUCTION MANUALDetcon Model PI-700PI-700 VOC Gas SensorsThis manual covers all ranges of PID based VOC SensorsDETCON, Inc.4055 Technology Forest Bl

Pagina 2 - Model PI-700 ii

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 6 of 54Do not mount in locations where temperatures will exceed the operating temperature limits o

Pagina 3 - Table of Contents

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 7 of 543.675"3/4" NPTExplosion Proof EnclosureJunction-BoxSensor AssemblySplash Guard(De

Pagina 4 - List of Tables

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 8 of 54NOTE:The Detcon Warranty does not cover water damage resulting from water leaking intothe e

Pagina 5 - 1. Introduction

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 9 of 54Table 1 Wire Gauge vs. DistanceAWG Wire Dia. Meters FeetOver-CurrentProtection22 0.723mm 70

Pagina 6 - 1.3 Modular Mechanical Design

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 10 of 54NOTE: If the 4-20mA output is not being used, a 100-250Ω resistor must be installed betwee

Pagina 7

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 11 of 54 Detcon Span Gas (See Detcon for Ordering Information). Recommended span gas is 50% of ra

Pagina 8 - 2. Installation

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 12 of 543. Operation3.1 Programming Magnet Operating InstructionsThe Operator Interface of the Mod

Pagina 9 - 2.2 Sensor Placement

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 13 of 543.2 Operator InterfaceThe operating interface is menu-driven via the two magnetic program

Pagina 10 - 2.4 Mounting Installation

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 14 of 54Software FlowchartdecdecmA Output = XX.XXSensor Life XXX%Last Cal XX DaysGas Factor = XXZe

Pagina 11 - 2.5 Electrical Installation

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 15 of 543.4 Calibration Mode3.4.1 AutoZeroThe AutoZero function is used to zero the sensor. Local

Pagina 12 - 2.6 Field Wiring

Model PI-700Model PI-700 ii

Pagina 13 - Model PI-700

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 16 of 54Material Requirements: Detcon PN 327-000000-000 MicroSafe™ Programming Magnet Detcon PN

Pagina 14 - 2.7 Initial Start Up

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 17 of 54magnet over PGM2 for 3 seconds to execute AutoSpan (or allow to timeout in 5 seconds if Au

Pagina 15

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 18 of 54NOTE 4: If the sensor fails the clearing time criteria, a “Clearing Fault” will be declare

Pagina 16 - LED Display

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 19 of 54Sensor Model TypeThe menu item appears as: “Model PI-700”Current Software VersionThe menu

Pagina 17 - 3.2 Operator Interface

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 20 of 54When the status list sequence is complete, the ITM will revert to the “View Sensor Status”

Pagina 18 - 3.3 Normal Operation

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 21 of 54When the AutoSpan value is between 101 and 1000, the adjustment increment is 50When the Au

Pagina 19 - 3.4 Calibration Mode

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 22 of 54“Set Range”). The display will then switch to “XXX“(where XXX is the current Range). Swipe

Pagina 20

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 23 of 54The menu item appears as: “Set Zero Offset”From the “Set Zero Offset” text scroll, hold th

Pagina 21

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 24 of 54From the “Restore Defaults” text scroll, hold the programming magnet over PGM2 un

Pagina 22 - 3.5 Program Mode

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 25 of 543.6.2 Fault Diagnostic/Failsafe FeaturesFail-Safe/Fault SupervisionModel PI-700 sensors ar

Pagina 23

Model PI-700Model PI-700 iiiTable of Contents1. Introduction ...

Pagina 24 - 3.5.2 Set AutoSpan Level

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 26 of 54condition has been cleared. If a Sensor Fault occurs, the 4-20mA signal will be set at 0mA

Pagina 25 - 3.5.4 Set Range

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 27 of 544. RS-485 Modbus™ ProtocolModel DM-700 sensors feature Modbus™ compatible communications p

Pagina 26 - 3.5.6 Set Zero Offset

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 28 of 54FC REG Content Description R/W Content DefinitionValue Meaning Range03/0640012 Special #2

Pagina 27 - 3.5.7 Signal Output Check

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 29 of 545. Service and MaintenanceCalibration FrequencyIn most applications, quarterly span calibr

Pagina 28 - 3.6 Program Features

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 30 of 54filter may vary depending on the application; however, it is advised to change it out at l

Pagina 29

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 31 of 54All piD Sensor Cells contain six user replaceable components:Filter Cap SpacerFilter Media

Pagina 30

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 32 of 54Figure 18 Removal of Filter Media4. Using the Exacto Blade, remove the spacer and set it a

Pagina 31 - Table 3 Modbus™ Registers

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 33 of 54Figure 21 Removal of LampCleaning the LampFigure 22 Lamp cleaningWearing gloves grab the l

Pagina 32 - Gas/Units String

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 34 of 54Reassembly1. Install the lamp into the sensor, making sure that the lamp’s metalized pads

Pagina 33 - 5. Service and Maintenance

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 35 of 544. Place the spacer around the assembly.Figure 27 Spacer installation5. Place the filter m

Pagina 34 - Avoid contact with crystals

Model PI-700Model PI-700 ivTable of FiguresFigure 1 Typical Sensor Cell...

Pagina 35 - Figure 16 Sensor Cell Parts

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 36 of 54Visual InspectionThe Sensor should be inspected annually. Inspect for signs of corrosion,

Pagina 36 - Figure 19 Removal of Spacer

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 37 of 54Figure 31 Sensor Cell and ITM Matingd) Thread the Splash Guard Adapter onto the ITM to a s

Pagina 37 - Figure 23 Polishing the Lamp

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 38 of 545.4 Replacement of PI-700 Sensor Assemblya) Remove the power source from the sensor assemb

Pagina 38 - Figure 25 Lamp seating

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 39 of 546. Troubleshooting GuideRefer to the list of Failsafe Diagnostic features listed in Sectio

Pagina 39 - Figure 29 Replacing the Cap

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 40 of 54 Verify adequate Sensor Life. Clean or replace the PID lamp. Replace the plug-in VOC se

Pagina 40 - Figure 30 Sensor Assembly

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 41 of 54 Verify field wiring is properly shielded and grounded. Contact Detcon to optimize shiel

Pagina 41 - 5.3 Replacement of ITM

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 42 of 547. Customer Support and Service PolicyDetcon HeadquartersShipping Address: 4055 Technology

Pagina 42

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 43 of 548. PI-700 Sensor WarrantyIntelligent Plug-in Sensor WarrantyDetcon Inc. warrants, under no

Pagina 43

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 44 of 549. Appendix9.1 SpecificationsSystem SpecificationsSensor Type: Continuous diffusion/adsorp

Pagina 44

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 45 of 54Weight: 2 lbs; 0.907kg (sensor only)6 lbs; 2.72kg (w/aluminum j-box)9 lbs; 4.08kg (w/stain

Pagina 45

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 1 of 541. Introduction1.1 DescriptionDetcon Model PI-700 VOC gas sensors are non-intrusive “Smart”

Pagina 46

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 46 of 549.2 Gas Reference TableTable 5 Gas Factor TableCompound Name Synonym/Abbreviation FormulaR

Pagina 47 - 8. PI-700 Sensor Warranty

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 47 of 54Compound Name Synonym/Abbreviation FormulaResponseFactor1ConfirmedValueIP (eV) TWACarbon d

Pagina 48 - 9. Appendix

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 48 of 54Compound Name Synonym/Abbreviation FormulaResponseFactor1ConfirmedValueIP (eV) TWADichloro

Pagina 49

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 49 of 54Compound Name Synonym/Abbreviation FormulaResponseFactor1ConfirmedValueIP (eV) TWAFurfuryl

Pagina 50 - 9.2 Gas Reference Table

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 50 of 54Compound Name Synonym/Abbreviation FormulaResponseFactor1ConfirmedValueIP (eV) TWALimonene

Pagina 51

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 51 of 54Compound Name Synonym/Abbreviation FormulaResponseFactor1ConfirmedValueIP (eV) TWANitropro

Pagina 52

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 52 of 54Compound Name Synonym/Abbreviation FormulaResponseFactor1ConfirmedValueIP (eV) TWATetrahyd

Pagina 53

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 53 of 549.3 Spare Parts, Sensor Accessories, Calibration EquipmentPart Number Spare Parts927-P2550

Pagina 54

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 54 of 549.4 Model PI-700 Engineering Drawings1) PI-700 Series Breakaway and Wiring2) PI-700 Series

Pagina 55

(+)mA(-)A(+)B(-)WhtBluRedGrnBlkDRAWING NO.3207-1REV4JOB NO.NASIZEASensor Wiringto Junction BoxIntelligent Transmitter Module (ITM)CustomerSupplied Wir

Pagina 56

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 2 of 54programming tool, thus allowing non-intrusive operator interface with the ITM. Calibration

Pagina 57

Model DM-700This page left intentionally blankShipping Address: 4055 Technology Forest Blvd., The Woodlands Texas 77381Mailing Address: P.O

Pagina 58 - 9.1 Revision History

Mounting Hole6-32 threadedGround PointMountingBoltWall (or othermounting surface)Use Spacers to movethe J-Box and SensorAssembly away from thewall at

Pagina 59 - Ground point

Model DM-700This page left intentionally blankShipping Address: 4055 Technology Forest Blvd., The Woodlands Texas 77381Mailing Address: P.O

Pagina 60 - Model DM-700

DRAWING NO.3207-3REV4JOB NO.NASIZEA5.5" 3.95"5.2"Detcon's AluminumExplosion ProofJunction-Box(Condulet)4" NPT PortPlug unuse

Pagina 61 - Wiring, Dimensional

Model DM-700This page left intentionally blankShipping Address: 4055 Technology Forest Blvd., The Woodlands Texas 77381Mailing Address: P.O

Pagina 62

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 3 of 54Housing BottomLocking Set-ScrewSplash GuardIntelligent ransmitter Module (ITM)Microprocesso

Pagina 63 - Junction-Box

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 4 of 542. Installation2.1 ATEX Operational Guidelines for Safe Use1. Install sensor only in areas

Pagina 64

Model PI-700PI-700 Instruction Manual Rev. 2.5 Page 5 of 542.2 Sensor PlacementSelection of sensor location is critical to the overall safe performanc