detcon inc.
Detcon MicroSafe
FP-524HT Combustible Gas Sensor (0-100% LEL)
Specialized Version For High Temperature Operation of Sensor Head
Operator’s Installation & Instruction Manual
May,18 2010 • Document #3428 • Version 0.1
CAUTION:
Before operating the Model FP-524HT sensor, read this manual thoroughly and verify that the
configuration of default factory settings are appropriate and correct for your application.
Vista de pagina 0
1 2 3 4 5 6 ... 21 22

Indice de contenidos

Pagina 1 - Detcon MicroSafe

detcon inc.Detcon MicroSafe™FP-524HT Combustible Gas Sensor (0-100% LEL)Specialized Version For High Temperature Operation of Sensor HeadOperator’s In

Pagina 2 - Table of Contents

There is a limit 0.5 ohm maximum resistance drop per wire over the seperation distance.AWG Maximum Seperation (feet)20 5018 7516 12514 175 Reference f

Pagina 3 - 3.0 DESCRIPTION

a) FP-524HT “Fault” LED is off.b) A temporary upscale reading may occur as the sensor heats up. This upscale reading will clear to “0”% within 1-2 min

Pagina 4 - Display Contrast Adjust

face plate. DO NOT remove the glass lens cover to calibrate or change programming parameters. Two switcheslabeled “PGM 1” and “PGM 2” allow for comple

Pagina 5 - Functional

Model FP-524HT Combustible Gas Sensor PG.13MethylethylketoneCyclohexaneBenzeneHydrogen SulphideMethyl n-propylketoneToluene2,3-DimethylpentaneTrieth

Pagina 6 - 3.4 OPERATING SOFTWARE

3.7.2 Verification of Target Gas and Calibration Gas ConfigurationVerification of target gas and calibration gas configuration is obtained via intera

Pagina 7

b) Next, scroll to the “SET CAL FACTOR” listing and then hold the programming magnet over “PGM 1” for 3seconds. The menu item appears as “CAL FACTOR #

Pagina 8 - 3.5 INSTALLATION

the instructions in section 3.9 and make note of the setting found in listing number 4. The item appears as“CalLevel @ xx%”.b) If the calibration gas

Pagina 9 - 3/4" NPT

3.9 STATUS OF PROGRAMMING, TARGET GAS, CALIBRATION GAS, CALIBRATION LEVEL, SENSOR LIFE, AND BRIDGE VOLTAGEThe programming menu has a programming stat

Pagina 10 - FP-524C-RS

dropped to 0 mA until the Fault is corrected.Fail-Safe/Fault SupervisionModel FP-524HT MicroSafe™ sensors are programmed for fail-safe operation. Any

Pagina 11 - Material Requirements

1. Check Heater Voltage Setting (should be 2.7V C-Style and 2.2V J-Style) and check heater voltage at the sensor ifremote mounted.2. Verify correct ca

Pagina 12 - Figure #6

Table of Contents3.0 Description3.1 Principle of Operation3.2 Application3.3 Specifications3.4 Operating Software3.5 Installation3.6 Start-up3.7 Targe

Pagina 13 - Gas KGas

3.13 SPAREPARTSLIST613-120000-700 Splashguard with Cal Port600-003427-000 FP-High Temp Splashguard Adapter365-037020-16H FP-HT Sensor Assembly 899-07

Pagina 14 - Material Requirements:

expiration of the warranty. All warranties and service policies are FOB the Detcon facility located in TheWoodlands, Texas.3.16 SOFTWARE FLOW CHARTMod

Pagina 15 - 3.8 CALIBRATION

Model FP-524C Combustible Gas Sensor PG.22

Pagina 16 - Additional Notes

3.0 DESCRIPTIONDetcon MicroSafe™ Model FP-524HT, combustible gas sensors are non-intrusive “Smart” sensors designed todetect and monitor combustible

Pagina 17 - 3.10 PROGRAM FEATURES

3.0.2 Microprocessor Control CircuitThe control circuit is microprocessor based and is packaged as a plug-in field replaceable module, facilitating e

Pagina 18 - 3.12 TROUBLE SHOOTING GUIDE

3.1 PRINCIPLE OF OPERATIONMethod of detection is by a controlled rate of diffusion/adsorption. Air and gas diffuse through a sintered stainlesssteel

Pagina 19

3.2 APPLICATIONModel FP-524HT MicroSafe™ sensors are designed to detect and monitor combustible gas in ambient air in the rangeof 0-100% LEL. Minimum

Pagina 20 - 3.15 SERVICE POLICY

01. Normal Operationa) Current Status02. Calibration Modea) Zerob) Span03. Program Menua) Program Statusb) Target gas selection (gas K factor)c) Calib

Pagina 21 - Woodlands, Texas

The factory default setting is 2.70 VDC.3.5 INSTALLATIONOptimum performance of ambient air/gas sensor devices is directly relative to proper location

Pagina 22

imity to contaminants that may foul the sensor prematurely.Note: In all installations, the sensor element in SS housing points down relative to grade

Comentarios a estos manuales

Sin comentarios