Sentinel CX
Sentinel CX Sensor Station IM Rev. 1.2 Page 16 of 16
4. Recharging the Internal Battery Pack
4.1 Non-Hazardous Area Location
At a safe time interval prior to full discharge of the internal battery pack, relocate the CXT Controller to a
non-hazardous area that has suitable 110 VAC or 220 VAC AC power receptacles available.
4.2 Connecting to Mains Supply
Using the appropriate Battery Charging Accessory product (PN 976-0003BC-00T for 110 VAC or PN 976-
0003BC-220 for 220 VAC), find the corresponding Mains Supply receptacle in the non-hazardous area and
plug-in the pronged end of the cable. Connect the Turck connector to the external port labeled external
power. Turn on the power switch and begin charging. Operate the charger for the necessary time it takes
to accomplish a full charge.
CAUTION
Only the Mains supply cord that is supplied with the Detcon-approved Battery
Charger Accessory product shall be used. Use of any other Mains supply cords will
impair the safety of this device.
Comentarios a estos manuales