Model FP-624D-HT
FP-624D-HT Instruction Manual Rev. 1.1 Page 40 of 44
9. Appendix
9.1 Specifications
Sensor Type: Continuous diffusion/adsorption type
Matched-Pair Catalytic Bead type
Sensor Life: 3-5 years typical
Measuring Ranges: 0-100% LEL
Accuracy/ Repeatability: ± 3% LEL in 0-50% LEL range, ± 5% LEL in 51-100% LEL range
Response Time: T50 < 10 seconds, T90 < 30 seconds
Electrical Classification: Class I, Division 1, Groups B, C, D
Sensor Warranty: 1 year
Transmitter Warranty: 2 year
Environmental Specifications
Operating Temperature: -40°C to +175°F; -40°C to +75°C (Transmitter Electronics
-40°C to +302°F; -40°C to +150°C (HT Sensor Head)
Storage Temperature: -40°C to +75°C
Operating Humidity: 0-99% RH (Non-condensing)
Operating Pressure: Ambient ± 10%
Electrical Specifications
Input Voltage: 12-28 VDC
Power Consumption: Normal operation = 68mA (<1.7 watt); Maximum = 87mA (2 watts)
RFI/EMI Protection: RFI Complies with ISA 92.0.01
Analog Output: Linear 4-20mA DC current
1000 ohms maximum loop load @ 24VDC
0mA All Fault Diagnostics
2mA In-Calibration
4-20mA 0-100% full-scale
22mA Over-range condition
Serial Output: RS-485 Modbus RTU
Baud Rate 9600 BPS (9600, N, 8, 1 Half Duplex)
Relay Outputs: Alarm 1, Alarm 2, and Fault
5A @ 250VAC
5A @ 30VDC